Monday, August 25, 2014

Capacitors Compressor


The capacitor is an electrical device that serves as a temporary storage of electrical charge, electrical charge bbesarnya capacity depends on the magnitude of the capacitor, the capacitor unit is farad (μ) and the Air Conditioner This capacitor is used as a first mover or compressor start capacitor use in accordance with their needs (PK) standard, when a capacitor with a size that does not fit the compressor will not spin and if the size is too big, it will cause the amperage to be high capacitors AC 1/2 hp compressor uses capacitors usually 15μf, 3/4 s / d 1 pk = 25μf- 30μf (tolerance + 5%) and so on, so if you want to replace a broken AC capacitor to adjust the amount of air conditioning / tesrebut compressors, fan motors in air conditioner capacitor 1/2 - 2 pk using 1,2μf s / d 2μf (tolerance + 5% ) in connecting this capacitor must be careful not to dial wrong in the socket.

How to connect the capacitor to the compressor the compressor capacitor there are 2 pieces socket with 3 wires, 2 wires connected to the compressor terminal SCR, and one longer cable connected to a source of electrical current (+). 1 One cable (blue) of the capacitor is connected directly to the electric current (+) 2 of the wires (red color) of the capacitor connected to the compressor terminal S (starting) 3 One cable (blue) of the capacitor (join in capacitor with a cable that connects the current No. 1) is connected to the compressor terminal R (running) 4 cable (black) to terminal C (common) connect directly to the electric current (-) Once the socket connection to the compressor and capacitor had an ok stay colokin to outlet make sure the terminal SCR is correct.

No comments:

Post a Comment